tologo Upgrade to TO3000 3D+

Installing and registering TO3000 3D+

TO3000 3D can be installed and run along with earlier versions of TO3000 for evaluation purposes.

To upgrade from TO3000 V7, TO3000 V8, TO3000 V9.0, TO3000 V10 or TO3000 V11 to TO3000 3D+, you will need to take the following steps:

1. Install a new TO3000 3D+ onto the same PC as the old version and choose "Do not install database";

2. Run the TO3000 Database Converter;

3. Convert your database from a previous version of TO3000;

4. Register TO3000 3D+.

 

Converting from earlier versions of TO3000

Depending on the version of TO3000 you used before, you will have to do different things to transfer the data from your old database  into TO3000 3D+

TO3000 3D

The only thing you need to do in this case if create a backup file and restore it.

  1. Launch your old TO3000 3D

  2. Go to Database Settings and click Backup to create a BAK file (see Backup).

  3. Launch TO3000 3D+

  4. Go to Database Settings, click Restore and select the created BAK file to restore the database (see Restore).

It is also possible to transfer Projetex database into TO3000 this way. You can create BAK files for Projetex on the "Database" tab of the Server Administrator utility on the Projetex server machine.

TO3000 11 and 10

The TO3000 3D+ Database Converter is an application supplied in the standard TO3000 3D+ setup file. It allows to continue the use of a database from TO3000 10 or 11. Running the TO3000 3D+ Database Converter is a convenient way to upgrade a database from TO3000 11 to operate with TO3000 3D+.

1. Run the utility from either the startup menu or by double-clicking the TO3000_3DConverter.exe file (the default location is ...\AIT\Translation Office 3000 Version 3D\Admin\DBConverter).

2. The TO3000 3D+ Database Converter will start with a list of requirements for it's successful operation. Make sure that the database of your previous installation of TO3000 10 or 11 is present on the computer and that the MS SQL server is set up and configured. Then click the Next button.

 

 

3. Navigate to the directory where your TO3000 10 or 11 database is installed. The database file should appear in the lower field. Select it and click Next.

 

 

4. Click the name of the MS SQL server that is available on your computer and click Next.

 

 

5. The utility will connect to the server. If you installed TO3000 3D+ with the demo or empty database, the utility will ask you to confirm that you wish to overwrite the existing database. Make a backup copy of it if you do not wish to lose it. When you are ready to proceed, check the box "Overwrite existing TO3000 3D+ database." and click Start.

 

 

6. The Data transfer will proceed automatically. Then it is finished, click Finish to close the utility.

 

TO3000 9 or older

IF you are using a version of TO3000 older than 10, you can use the TO3000, Version 11 Database Converter first. It is an application supplied in the standard TO3000 3D+ setup. It allows to transfer a database from Translation Office 3000 (Versions 7, 8, 9 and 10) into a form compatible with the TO 3000 3D Database Converter.

1. Run the converter from either the startup menu or by double-clicking the DBConverter.exe file (the default location is ...\AIT\Translation Office 3000 Version 3D\Admin\DBConverter10\).

2. Select your current version of the TO3000 database and click Next button.

3. Select the Create TO3000 11 Database radio button.

4. TO3000 11 Database Converter will automatically locate the installation of TO3000 and select the source database file to be transferred. If the program cannot find TO3000 database, click the Browse button, manually specify a path to the source database file and click the Next button.

5. Specify a directory in which the new database file should be generated and click the Next button.

6. Click the Start button to convert the database for TO3000 11.

7. Run the TO3000 3D+ Database Converter to convert the newly created database into one compatible with TO3000 3D+.

_bm3 IMPORTANT NOTE: Make sure that you convert the database under the same Language for non-Unicode programs as on your work computer. For example, if you have worked with French characters in a previous version of Projetex or TO3000, it is required to have French as the Language for non-Unicode programs in the Region and Language options of the computer, in which you perform the conversion of the TO3000 3D+ database.

How to change System Locale:

  • You must be logged in with an account that has administrative privileges in order to change the system locale.

  • The appropriate language packs should be installed on the operating system.

 

View the System Locale settings for Windows

  1. Click Start then Control Panel

  2. Click Clock, Language and Region

  3. Windows 10, Windows 8: Click Region
    Windows 7: Click Region and Language
    Windows XP: Click Regional and Language Options
    The Region and Language options dialog appears.

  4. Click the Administrative tab
    On Windows XP, click the Advanced tab
    If there is no Advanced tab, then you are not logged in with administrative privileges.

  5. Under the Language for non-Unicode programs section, click Change system locale and select the desired language.

  6. Click OK

  7. Restart the computer to apply the change.

 

_bm3 NOTE: If you are installing TO3000 3D on a new PC, ensure that the Business folder used by the previous version of TO3000 is copied to the new location.

_bm3 NOTE: Templates, CAT schemes and Local Custom Filter settings will not be imported. Please move them manually to the TO3000 3D+ setup folder. Listed below locations of templates, CAT schemes and Local Custom Filter settings in TO3000 V8, TO3000 V9.0, TO3000 V10, TO3000, Version 11 and in TO3000 3D:

Templates

·TO3000 V8: ...\Translation Office 3000 V8\Templates\

·TO3000 V9.0: ...\Translation Office 3000 Version 9.0\Templates\

·TO3000 V10: C:\Users\Public\Documents\AIT\TO3000, Version 10\Templates\

·TO3000, Version 11: C:\Users\Public\Documents\AIT\TO3000, Version 11\Templates\

·TO3000 3D: C:\Users\Public\Documents\AIT\TO3000, Version 3D\Templates\

·TO3000 3D+: C:\Users\Public\Documents\AIT\TO3000, Version 3D+\Templates\

 

CAT schemes

·TO3000 V8: ...\Translation Office 3000 V8\System\Schemes\

·TO3000 V9.0: ...\Translation Office 3000 Version 9.0\Schemes\

·TO3000 V10: C:\Users\Public\Documents\AIT\TO3000 3D+\Schemes

·TO3000, Version 11: C:\Users\Public\Documents\AIT\TO3000, Version 11\Schemes

·TO3000 3D: C:\Users\Public\Documents\AIT\TO3000, Version 3D\CatCount 4\Schemes

·TO3000 3D+: C:\Users\Public\Documents\AIT\TO3000, Version 3D+\CatCount 4\Schemes

 

Local Custom Filter settings

·TO3000 V8: ...\Translation Office 3000 V8\Filters\

·TO3000 V9.0: ...\Translation Office 3000 Version 9.0\Filters\

·TO3000 V10: C:\Users\Public\Documents\AIT\TO3000, Version 10\Filters\

·TO3000, Version 11: ...C:\Users\Public\Documents\AIT\TO3000, Version 11\Filters\

 

_bm3 NOTE: In Windows XP, the C:\Users\Public\Documents\AIT\... folder corresponds to the C:\Documents and Settings\All Users\Documents\AIT\... folder.

 

_bm2

 

See also:

TO 3000 3D Setup